Q-2, r. 22 - Regulation respecting waste water disposal systems for isolated dwellings

Full text
11.4. Discharge standard: The SS concentration of the effluent of the primary treatment system referred to in section 11.1 must be less than 100 mg/litre. The standard is exceeded where the concentration in 2 samples collected in a 60-day period exceeds the above amount.
O.C. 786-2000, s. 16.